HERZZIEGEL

TECHNICAL INFORMATION

Size (approx.) 230 x 420 mm
Covering width on av. approx.
Max. coverage width (approx.)
Covering width min. approx.
207 mm
209 mm
205 mm
Covering length on av. approx.
Max. gauge (approx.)
Min. gauge (approx.)
344 mm
350 mm
337 mm
Average tile requirement (approx.)
Brickware max. approx.
Tile requirement min. (approx.)
14.1 pcs/m²
14.5 pcs/m²
13.7 pcs/m²
Weight per m² (approx.)
Weight per pallet (approx.)
Unit weight (approx.)
43.7 kg/m²
769 kg
3.1 kg/Stück
Pcs per pallet
Pcs per mini-pack
240 Unit
5 piece

TECHNICAL INFORMATION

AREA OF USE

VALID FOR GERMANY
Roof pitch DUO longlife ND extra (Germany)≥ 22 °
Roof pitch DUO extra (Germany)≥ 22 °
Roof pitch QUATTRO longlife extra (Germany)≥ 10 °
Roof pitch TRIO longlife extra (Germany)≥ 18 °
Roof pitch TRIO extra (Germany)≥ 18 °
Roof pitch UNO classic (Germany)≥ 24 °
Roof pitch UNO classic (Germany)≥ 24 °
VALID FOR AUSTRIA
Roof pitch DUO longlife ND extra (Austria)≥ 22 °
Roof pitch DUO extra (Austria)≥ 22 °
Roof pitch QUATTRO longlife extra (Austria)≥ 20 °
Roof pitch TRIO extra (Austria)≥ 22 °
Roof pitch TRIO longlife extra (Austria)≥ 22 °

LAF-/FLA-VALUES

LAF-/FLA VALUES IN MM FOR 30x50-BATTENS
Ridge tileDN20°25°30°35°40°45°50°
PRU 2.5 pcs./m.LAF70656060555050
PRU 2.5 pcs./m.FLA100908580656050
PZ 2.5 pcs./m.LAF70656060555050
PZ 2.5 pcs./m.FLA80706555504535
LAF-/FLA VALUES IN MM FOR 40x60-BATTENS
Ridge tileDN20°25°30°35°40°45°50°
PRU 2.5 pcs./m.LAF70605555504035
PRU 2.5 pcs./m.FLA1101009590757060
PZ 2.5 pcs./m.LAF70605555504035
PZ 2.5 pcs./m.FLA90807565605545
LAF-/FLA VALUES IN MM FOR 50x50-BATTENS
Ridge tileDN20°25°30°35°40°45°50°
PRU 2.5 pcs./m.LAF65555045403025
PRU 2.5 pcs./m.FLA120110105105908580
PZ 2.5 pcs./m.LAF65555045403025
PZ 2.5 pcs./m.FLA100908580757065
                                                                       

Assortment for roof details and wind suction protection